← Products

WEESION / W10 SERIES

W10U

EC fan · 0–10 V

Advanced Fan Coil & Chilled Beam Remote I/O Controller (BACnet/Modbus)

EC fanHeating and cooling actuator: ON/OFF or 0–10 VVAVTemperatureActive sensor24 V DC power outputDigital inputBACnetModbus
237,00 €
Contact us for B2B pricing.
Instruction manual

Every connection has a purpose.

Model-specific specifications, grouped by function. Refer to the manual for detailed diagrams, wiring conditions and configuration.

Power supply

  • Power supply 230Vac or USB-C (only for testing and settings reasons),

Control & outputs

  • EC fan control, with analog output 0-10Vdc
  • 2x more analog outputs 0-10V for heating, cooling or VAV box conrol
  • 2x digital outputs for ON/OFF (230Vac, 24Vac, 24Vdc) valve control,
  • 24Vdc output for use with digital outputs or as a power supply of external devices,

Sensors & inputs

  • temperature sensor input PT1000,
  • digital input, for window contact, occupancy sensor or energy saving contact or universal use
  • analog input 0-10V (CO2 or other sensors),

Communication

  • BACnet MS/TP or Modbus RTU communication.

USB-C is used for configuration and testing; follow the model’s manual for the operating installation.

Full product technical description

W10 series are small communication enabled (BACnet MS/TP or Modbus RTU) multifunctional fan coil or chilled beam remote I/O controllers, developed for intelligent room control applications and BMS integration. No other unnecessary control boxes or cables are required in the installation. All modules are equipped with USB-C connection for communication settings.

  • Power supply 230Vac or USB-C (only for testing and settings reasons),
  • EC fan control, with analog output 0-10Vdc
  • 2x more analog outputs 0-10V for heating, cooling or VAV box conrol
  • 2x digital outputs for ON/OFF (230Vac, 24Vac, 24Vdc) valve control,
  • 24Vdc output for use with digital outputs or as a power supply of external devices,
  • temperature sensor input PT1000,
  • digital input, for window contact, occupancy sensor or energy saving contact or universal use
  • analog input 0-10V (CO2 or other sensors),
  • BACnet MS/TP or Modbus RTU communication.

For more information refer to the Instruction manual.

The right module for the task.

W10U is part of the W10 series for fan coils and chilled beams. Your fan type, valve actuators and required sensors determine the module selection.

Continuous EC fan control

A 0–10 V analogue signal lets the supervisory system set the speed of an EC fan. Select the module according to the motor type and the outputs your application requires.

Part of your BMS

BACnet MS/TP or Modbus RTU carry information between the module and the supervisory system. You define the control logic in the BMS or DDC to suit your project.

I/O close to the equipment

Connect the temperature sensor, contact and other peripherals to the module near the fan coil or chilled beam. Available connections depend on the selected model.

A clear path to installation.

01

Select the I/O

Match the requirements of the fan, actuators and sensors to the selected module’s inputs and outputs.

02

Prepare the module

Wire the module and peripherals on the workbench. Use USB-C to configure communication parameters.

03

Connect to the BMS

Verify communication and individual I/O points using a configured BACnet or Modbus DDC controller.

W10U instruction manual